Security-systems TS2000 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Bezpečnost Security-systems TS2000. Security Systems TS2000 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 20
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
TS2000
Installation & User Guide
Compatible Equipment
CPA6 OM - Output Module
9040 - Loudspeaker
DC54/58 - Digital Communicators
496529 Issue A 1 of 20 TS2000
Zobrazit stránku 0
1 2 3 4 5 6 ... 19 20

Shrnutí obsahu

Strany 1 - Installation & User Guide

TS2000Installation & User GuideCompatible EquipmentCPA6 OM - Output Module9040 - LoudspeakerDC54/58 - Digital Communicators496529 Issue A 1 of 20

Strany 2 - OVERVIEW

TS2000TS2000 10 of 20 496529 Issue AOUT DOUT COUT BOUT AI/P C+I/P A+I/P B+I/P D+0V+12VDIRECTION -DIRECTION +DATA UP -DATA UP +DATA DOWN -DATA DOWN +Co

Strany 3 - 3 of 20 TS2000

TS2000496529 Issue A 11 of 20 TS2000SettleRVSPKRACCESSOUTLXOUTWARDCONTROL0V+12VWARD SETWARD EXITSET FAILWARD ALARMTo nc contacts ofAccess device*To nc

Strany 4 - 4 of 20 496529 Issue A

TS2000TS2000 12 of 20 496529 Issue A4k7Tamper SwDetector SwNext PIR or DetEOL Res2k2Exit Terminatorn.c. (Or n.o.) ContactsFor n.o contacts setInverted

Strany 5 - 5 of 20 TS2000

TS2000Key FunctionsEngineer Reset1. Enter your engineer’s code default 1234, you arenow in Engineer’s Mode2. Press 0 in quit to unset.Loading Defaults

Strany 6 - 6 of 20 496529 Issue A

Define Circuit TextTS2000TS2000 14 of 20 496529 Issue ASTEP ACTION DISPLAY REMARKS1 NO* Press < YES > toDEFINE CIRCUIT TEXTPress YES to Define C

Strany 7 - 7 of 20 TS2000

TS2000 DictionaryTS2000496529 Issue A 15 of 20 TS2000001 A 056 CEILING 111 ENTRANCE002 ABOVE 057 CELL 112 ENTRY003 ACCESS 058 CELLAR 113 EQUIPMENT004

Strany 8 - 8 of 20 496529 Issue A

TS2000 Dictionary Cont’dTS2000TS2000 16 of 20 496529 Issue A164 INFRA-RED 217 METER 271 PORCH165 INSIDE 218 MEZZANINE 272 POST166 INSTRUCTORS 219 MICR

Strany 9 - 9 of 20 TS2000

TS2000 Dictionary Cont’dTS2000496529 Issue A 17 of 20 TS2000325 SITE 381 TRAP 431 11326 SITTING 382 T.V. 432 12327 SLIDING 383 TWIN 433 13328 SMOKE 38

Strany 10 - 10 of 20 496529 Issue A

TS2000Programmable OuputsThe programmable outputs from the NU and the REM,arereferred toastheNodeOutputsandareactivatedinresponse to various condition

Strany 11 - 11 of 20 TS2000

TS2000496529 Issue A 19 of 20 TS2000Menu No Menu Passcode Level1 Start Set Sequence 1, 2, 3, 4, 5, 6User2 Unset Wards 1, 2, 3, 4, 5, 63 View Circuits

Strany 12 - 12 of 20 496529 Issue A

OVERVIEWIntroductionThe Intruder Alarm Control System TS2000 is provided forlarge domestic and general commercial intrudersystems conforming to BS 473

Strany 13 - Key Functions

TS2000 20 of 20 496529 Issue ATS2000This page intentionally left blank

Strany 14 - 14 of 20 496529 Issue A

Additional EquipmentsWard Control Unit (WCU): When fitted the WCU will allowa group of circuits, whichare designated a Ward, to beSet and Unset using

Strany 15 - 15 of 20 TS2000

Schematic Block DiagramTS2000 4 of 20 496529 Issue ATS2000WARDCONTROLUNIT*REMOTEPOWERSUPPLYUNIT*NODE ORREMOTE KEYPADNo 32 (MAX)NODE ORREMOTE KEYPADNo

Strany 16 - 16 of 20 496529 Issue A

TS2000 System Options - Schematic496529 Issue A 5 of 20 TS2000TS2000SIB*PIB*PSUDC3(M)*OR D 3*CPMAINBOARD8 ProgrammableoutputsDC 28DigicomPSTN LineCent

Strany 17 - 17 of 20 TS2000

EquipmentSystem SpecificationSupply Voltage: 240V + or - 10% 30W 50 HzBattery: 12V 6AhZones: 128 maximumOutputs: 128 remote 8 local maximumUnit Dimens

Strany 18 - 18 of 20 496529 Issue A

Node Unit (NU)The NU comprises a smalltwo part polycarbonate casecontaining a single pcb on which are terminal blocks.The unit is connected to the con

Strany 19 - 19 of 20 TS2000

TS2000TS2000 8 of 20 496529 Issue AConnect to Control NetworkSee Fig 6.For Mimic. Connect toCPA6.OM module.For SAB Tamper.Link to 0V if not usedRelay

Strany 20 - 20 of 20 496529 Issue A

TS2000496529 Issue A 9 of 20 TS2000Use for Networkpower to NU andREM onlyCable 6 or 8 core 7/0.2mmMaximum length 100m between each unit.Using 8 core c

Komentáře k této Příručce

Žádné komentáře